• Flow.Temperature.Pressure.Level.Pumps

  • Measurement.Repair.Environmental.Calibration

  • UKAS.NADCAP.Traceable.Certification

 

Digital / Analogue Mass Gas Flowmeter

Can we help?
Digital / Analogue Mass Gas Flowmeter
M Series

The M series mass flowmeter was designed to be used as a stand-alone device. With the native display, a user can easily change the configuration of the meter without the need for computers, complicated software or scripts. The M series mass flowmeter also measures pressure, temperature and volumetric flow in addition to mass flow.

MS Series - Aggressive Gases

The MS series of 316L Stainless Steel aggresive gas compatible mass flowmeters retain the same functionality as well as fit and finish of the standard M series mass flowmeters.

The MS series is built from 316L Stainless Steel and uses encapsulated 316L Stainless Steel sensors in the flow path. A variety of sealing material are available, including FFKM, EPDM, Viton, Buna-n, etc. depending upon your application and needs.

FEATURES
  • Response time of 10 milliseconds (adjustable)
  • Turndown ration of 100:1
  • Push button interface
  • Accuracy of ±0.8% of reading + 0.2% of full scale
  • 30 standard gas calibration included
MEASURED PARAMETERS
  • Mass flow
  • Volumetric flow
  • Pressure (psia)
  • Temperature (ºC)
All meters are supplied with National Institute of Standards and Technology (NIST) traceable calibration certificate.

Full Product Specification

Flow Range 0.5 cm³/min - 1,500 L/min (@ ATP)
Accuracy*¹ ±0.8% of reading + 0.2% of full scale
Repeatability ±0.2% FS
Adjustable Response Time 10 ms
Turndown Ratio 100:1
Pressure Drop 1.0 psid @ 0.5-50 cm³/min
5.5 psid @ 500 L/min
6.0 psid @ 1,000 L/min
9.0 psid @ 1,500 L/min
5.0 psid @ 2,000 L/min
Maximum Pressure 145 psig
Operating Temperature -10 to 50ºC
Wetted Materials Aluminium, 303 and 302 Stainless Steel, Viton®, Silicon Rubber and Glass Reinforced Nylon
Power Supply 7-30V DC, 30mA typical
Output 0-5V DC (4-20mA or 0-10V DC optional)
Electrical Connection 8 pin mini-DIN or DB-15
30 gas calibrations included: acetylene, air, argon, butane, carbon dioxide, carbon monoxide, ethane, ethylene, helistar® A1025, helium, hydrogen, iso-butane, krypton, methane, neon, nitric oxide, nitrogen, nitrous oxide, oxygen, propane, stargon® CS, sulphur hexafluoride, xenon, 75% argon + 25% CO₂, 90% argon + 10% CO₂, 92% argon + 8% CO₂, 98% argon + 2% CO₂, 75% argon + 25% helium, 95% argon + 5% methane, 75% helium + 25% argon, 75% CO₂ + 25% argon.
Corrosive/Aggressive gases compatible with MS series: nitric oxide (to 100%), nitrogen triflouride (to 100%), ammonia (to 100%), chlorine (to 100%), hydrogen sulfide (to 100%), sulfur dioxide (to 100%), propylene (to 100%), nitrogen dioxide (to 0.5% in an inert carrier), refrigerant gases (to 100%).
*¹High accuracy calibration available for accuracy to ±0.4% of reading + 0.2% of full scale.

Recommended Products





loading...

Major Credit Cards Accepted
Call us+44 (0)870 22 00 724 Email ussales@roxspur.com