GEN1300 Series 24V DC Power Supply
Can we help?
The GEN1300 is a DIN rail mounted power supply that provides a regulated 24V DC output @ 250mA from an AC supply ranging from 90 to 253VAC 50/60Hz.
Ideally suited to powering 24V process instrumentation and signal conditioning modules, the small size of the GEN1300 now enables many more units to be installed in a smaller space than was previously possible.
The high efficiency of the GEN1300 power supply and its very cool running operation ensures a lower ambient temperature rise and hence improved reliability.
Ideally suited to powering 24V process instrumentation and signal conditioning modules, the small size of the GEN1300 now enables many more units to be installed in a smaller space than was previously possible.
The high efficiency of the GEN1300 power supply and its very cool running operation ensures a lower ambient temperature rise and hence improved reliability.
Full Product Specification
SPECIFICATION @ 20°CInput
| Supply Range | 90-253VAC 50/60 Hz |
| Efficiency | 70% typ @ 230VAC 250mA |
| Protection | 1 Amp anti surge fuse recommended in live supply line (not supplied) |
| Filter | Inbuilt EMC Filter |
| Connections | Captive Screw Connections |
Output
| Voltage | 24V DC ± 0.5% @ 250mA Short Circuit Protected |
| Ripple | 100mV p-p |
| Indication | LED power on |
| Protection | IP20 |
| Isolation | 2500 V Flash Tested to Supply |
General
| Case Material | Polyamide (Grey) |
| Case Flammability | To UL94-VO VDE 0304, Part 3, Level IIIA |
| Mounting | Top Hat Rail to DIN EN 50022-35 |
| Protection | IP20 |
| Connections | Captive Screw Terminal |
| Cable Size | 4mm2 Solid/2.5mm2 Stranded |
| Case Size | 21.5mm wide x 60 x 60mm |
Approvals
| EMC | BS EN 61326 |
| Emissions | BS EN 50081 |
| Susceptibility | BS EN 50082 Electrical Safety BS EN 61010-1 |
Recommended Products
GEN500 Loop Powered Indicator
The GEN500 is a loop powered indicator which is designed for series connection into a 4/20mA current loop and to display digitally, in engineering units, the process variable represented by the current flow. The GEN500 needs only 1 volt from the loop. The GEN500X is a version approved for hazardous area use and requires 1.6 volts from the loop. Style Fand G housing will accommodate any suitable in head transmitter.
FEATURES
Smart Universal Temperature Transmitter
The GEN210 is a second generation ‘Smart’ in head temperature transmitter that accepts any commonly used temperature sensor, Slidewire transducer or Millivolt signal and converts the output to the industry standard 4-20 mA transmission signal.
The sensor type and range are easily programmed using a software package running under ‘Windows™’ on a PC which communicates, via an interface adapter,down the same pair of wires that carry the 4- 20 mA output signal. Sensor and span can be freely selected without the need for re-calibration.
Isolation is a standard feature, removing all ground loop effects as the input is electrically and physically isolated from the loop power supply (see the schematic below). The use of two micro-processors results in error-free data transmission across the isolation barrier.
The very small size coupled with the versatility of this universal transmitter make it the ideal choice for every temperature measurement application, resulting in lower stock holdings, greater operational flexibility and, in common with our other products, a low cost of ownership.
UKAS and Traceable Calibration
Roxspur Measurement & Control Ltd is an ISO 9001:2008 company, we offer UKAS and traceable calibration under BS/EN ISO17025 accredited procedures. Our certificate generation systems are purposely geared to meet the strict and specific requirement of the Aerospace industry.
Calibration
Based at our factory in Sheffield our accredited laboratories are available to provide either on-site or in-house calibration to either UKAS or national standards. We cover Temperature (up to 2,200ºC), Pressure (up to 1,200 bar), Flow (up to 2,500 L/min) and Electrical parameters and provide certification using the latest technology.
Our team of experienced on-site engineers hold accreditation for the on-site calibration of equipment including autoclaves, furnaces, thermocouples and probes, scales and balances, ovens and chambers, indicators and controllers, pressure and electrical. We cover the full spectrum of industry sectors. All calibration standards used meet the requirements of Table 3 of AMS 2750D, whether in the laboratory or on site, ensuring full compliance with the specification. To find out more about our on-site services please click here.
We supply thermocouples calibrated and certified to meet the requirements of Table 1 of AMS 2750D appropriate to customer specified usage.
Aerospace Heat Treatment Specialists
From the supply of a single thermocouple to fully managed service contracts, by working in partnership with our customers we can assist in obtaining and maintaining NADCAP approval. To find out more about our specialist aerospace services please click here.
Certification
Certificates generated are designed to meet the requirements of AMS 2750D with the option of UKAS certificates for added peace of mind.
GEN500 Loop Powered Indicator
The GEN500 is a loop powered indicator which is designed for series connection into a 4/20mA current loop and to display digitally, in engineering units, the process variable represented by the current flow. The GEN500 needs only 1 volt from the loop. The GEN500X is a version approved for hazardous area use and requires 1.6 volts from the loop. Style Fand G housing will accommodate any suitable in head transmitter.FEATURES
- Large 20mm LCD display
- Only 1 volt from loop
- Loop powered
- Stainless Steel case 100mm dial
- Sensor / wall / panel mount
- IP65 enclosure
Smart Universal Temperature Transmitter
The GEN210 is a second generation ‘Smart’ in head temperature transmitter that accepts any commonly used temperature sensor, Slidewire transducer or Millivolt signal and converts the output to the industry standard 4-20 mA transmission signal.The sensor type and range are easily programmed using a software package running under ‘Windows™’ on a PC which communicates, via an interface adapter,down the same pair of wires that carry the 4- 20 mA output signal. Sensor and span can be freely selected without the need for re-calibration.
Isolation is a standard feature, removing all ground loop effects as the input is electrically and physically isolated from the loop power supply (see the schematic below). The use of two micro-processors results in error-free data transmission across the isolation barrier.
The very small size coupled with the versatility of this universal transmitter make it the ideal choice for every temperature measurement application, resulting in lower stock holdings, greater operational flexibility and, in common with our other products, a low cost of ownership.
UKAS and Traceable Calibration
Roxspur Measurement & Control Ltd is an ISO 9001:2008 company, we offer UKAS and traceable calibration under BS/EN ISO17025 accredited procedures. Our certificate generation systems are purposely geared to meet the strict and specific requirement of the Aerospace industry.Calibration
Based at our factory in Sheffield our accredited laboratories are available to provide either on-site or in-house calibration to either UKAS or national standards. We cover Temperature (up to 2,200ºC), Pressure (up to 1,200 bar), Flow (up to 2,500 L/min) and Electrical parameters and provide certification using the latest technology.
Our team of experienced on-site engineers hold accreditation for the on-site calibration of equipment including autoclaves, furnaces, thermocouples and probes, scales and balances, ovens and chambers, indicators and controllers, pressure and electrical. We cover the full spectrum of industry sectors. All calibration standards used meet the requirements of Table 3 of AMS 2750D, whether in the laboratory or on site, ensuring full compliance with the specification. To find out more about our on-site services please click here.
We supply thermocouples calibrated and certified to meet the requirements of Table 1 of AMS 2750D appropriate to customer specified usage.
Aerospace Heat Treatment Specialists
From the supply of a single thermocouple to fully managed service contracts, by working in partnership with our customers we can assist in obtaining and maintaining NADCAP approval. To find out more about our specialist aerospace services please click here.
Certification
Certificates generated are designed to meet the requirements of AMS 2750D with the option of UKAS certificates for added peace of mind.