The unit is microprocessor based and provides high accuracy performance over a wide ambient operating temperature. Max/Min temperature buttons are provided on the front panel. Different sensor types are selected using a rotary switch on the rear of the product.
FEATURES
- Battery powered
- Large 4 digit LCD display
- Pt100, Ni120, Cu53, Cu100 sensors
- Push button Max/Min temperature
- 100mm Stainless Steel Dial gauge housing
- Sealed to IP65
Full Product Specification
SPECIFICATION @ 20ºC| GENERAL | |
| RTD Sensor | Pt100, Ni100, Ni120, Cu53 and Cu100 |
| Display | 4 digit LCD, 20mm high |
| Ambient Operating Temperature | -10 to 50ºC |
| Battery Type | 3.6V lithium AA 2.4 Ahr replaceable |
| Battery Life | 1 year minimum |
| Battery Low Alarm | Via display |
| Display Update | 2 seconds |
| CE | EMC to BS EN 61326:2006 |
| MECHANICAL | |
| Connection | 3 terminal screw block |
| Environmental Protection | IP65 |
DM660P - ACCURACY/STABILITY
| Sensor | Range ºC | Accuracy @ 20ºC | Temperature Stability |
| Pt100 3851 | -100 to 800 | ±0.2ºC ±0.1% of reading | ±0.015% full range / ºC |
| Pt100 391 | -100 to 630 | ||
| Pt100 392 | -100 to 630 | ||
| Pt100 393 | -100 to 800 | ||
| Ni100 | -50 to 170 | ||
| Ni120 | -70 to 260 | ||
| Cu100 | -80 to 250 | ||
| Cu53 | -40 to 180 | ±0.4ºC ±0.1% of reading |
Recommended Products
GEN500 Loop Powered Indicator
The GEN500 is a loop powered indicator which is designed for series connection into a 4/20mA current loop and to display digitally, in engineering units, the process variable represented by the current flow. The GEN500 needs only 1 volt from the loop. The GEN500X is a version approved for hazardous area use and requires 1.6 volts from the loop. Style Fand G housing will accommodate any suitable in head transmitter.
FEATURES
GEN640 Battery Powered Indicator
GEN700 Loop Powered Indicator
The GEN700 is a Loop Powered Indicator which incorporates a high efficiency LED display. Designed for use with our NM2 heads, the units are sealed to IP67. ATEX versions are available for use in hazardous areas using the NM2 head.
The unit is microprocessor based. Set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure. This device can have a number of standard linearisations applied, such as square root, or a custom characteristic can be entered.
FEATURES
UKAS and Traceable Calibration
Roxspur Measurement & Control Ltd is an ISO 9001:2008 company, we offer UKAS and traceable calibration under BS/EN ISO17025 accredited procedures. Our certificate generation systems are purposely geared to meet the strict and specific requirement of the Aerospace industry.
Calibration
Based at our factory in Sheffield our accredited laboratories are available to provide either on-site or in-house calibration to either UKAS or national standards. We cover Temperature (up to 2,200ºC), Pressure (up to 1,200 bar), Flow (up to 2,500 L/min) and Electrical parameters and provide certification using the latest technology.
Our team of experienced on-site engineers hold accreditation for the on-site calibration of equipment including autoclaves, furnaces, thermocouples and probes, scales and balances, ovens and chambers, indicators and controllers, pressure and electrical. We cover the full spectrum of industry sectors. All calibration standards used meet the requirements of Table 3 of AMS 2750D, whether in the laboratory or on site, ensuring full compliance with the specification. To find out more about our on-site services please click here.
We supply thermocouples calibrated and certified to meet the requirements of Table 1 of AMS 2750D appropriate to customer specified usage.
Aerospace Heat Treatment Specialists
From the supply of a single thermocouple to fully managed service contracts, by working in partnership with our customers we can assist in obtaining and maintaining NADCAP approval. To find out more about our specialist aerospace services please click here.
Certification
Certificates generated are designed to meet the requirements of AMS 2750D with the option of UKAS certificates for added peace of mind.
GEN500 Loop Powered Indicator
The GEN500 is a loop powered indicator which is designed for series connection into a 4/20mA current loop and to display digitally, in engineering units, the process variable represented by the current flow. The GEN500 needs only 1 volt from the loop. The GEN500X is a version approved for hazardous area use and requires 1.6 volts from the loop. Style Fand G housing will accommodate any suitable in head transmitter.FEATURES
- Large 20mm LCD display
- Only 1 volt from loop
- Loop powered
- Stainless Steel case 100mm dial
- Sensor / wall / panel mount
- IP65 enclosure
GEN640 Battery Powered Indicator
The GEN600 series of battery powered indicators accepts either an RTD (GEN640P) or a thermocouple (GEN640TC) input. Each device shows the temperature on a 4 digit LCD display. The unit is microprocessor based. The sensor type is selected from a simple to use menu system which is navigated by the use of three push buttons located on the rear of the display. This feature enables the user to easily configure the device in the field without the use of any other equipment. The GEN640P and GEN640TC are sealed into a cap. There are several mounting options including the SCH4 series of enclosures and a stainless steel option, the SCH15.
ATEX versions are available for use in hazardous dust and gas areas.
FEATURES
- Battery powered
- RTD or TC input options
- Push button configurable
- 4 digit display
- Housing ABS plastic or Stainless Steel
- Sealed to IP67
- ATEX approved in ABS housing
GEN700 Loop Powered Indicator
The GEN700 is a Loop Powered Indicator which incorporates a high efficiency LED display. Designed for use with our NM2 heads, the units are sealed to IP67. ATEX versions are available for use in hazardous areas using the NM2 head.The unit is microprocessor based. Set-up is achieved by means of three push buttons located on the underside of the module following a simple menu structure. This device can have a number of standard linearisations applied, such as square root, or a custom characteristic can be entered.
FEATURES
- 4-20mA loop powered
- Fully programmable by push buttons
- Custom linearisation
- 4 digit LED display
- ATEX approved
UKAS and Traceable Calibration
Roxspur Measurement & Control Ltd is an ISO 9001:2008 company, we offer UKAS and traceable calibration under BS/EN ISO17025 accredited procedures. Our certificate generation systems are purposely geared to meet the strict and specific requirement of the Aerospace industry.Calibration
Based at our factory in Sheffield our accredited laboratories are available to provide either on-site or in-house calibration to either UKAS or national standards. We cover Temperature (up to 2,200ºC), Pressure (up to 1,200 bar), Flow (up to 2,500 L/min) and Electrical parameters and provide certification using the latest technology.
Our team of experienced on-site engineers hold accreditation for the on-site calibration of equipment including autoclaves, furnaces, thermocouples and probes, scales and balances, ovens and chambers, indicators and controllers, pressure and electrical. We cover the full spectrum of industry sectors. All calibration standards used meet the requirements of Table 3 of AMS 2750D, whether in the laboratory or on site, ensuring full compliance with the specification. To find out more about our on-site services please click here.
We supply thermocouples calibrated and certified to meet the requirements of Table 1 of AMS 2750D appropriate to customer specified usage.
Aerospace Heat Treatment Specialists
From the supply of a single thermocouple to fully managed service contracts, by working in partnership with our customers we can assist in obtaining and maintaining NADCAP approval. To find out more about our specialist aerospace services please click here.
Certification
Certificates generated are designed to meet the requirements of AMS 2750D with the option of UKAS certificates for added peace of mind.