Products > Flow > Electromagnetic Flowmeters > Electromagnetic Flowmeter Model 910
The Model 910 Electromagnetic Flowmeter is an instrument designed for measuring and indicating flow and total volume of conductive liquids. The flowmeter measures both positive and negative flow. As there are no moving parts in the profile, the device can be used to measure extremely dirty liquids containing solids. The flowmeters have been designed to work in all process industries including chemical, water and wastewater. The Model 910 also boasts diagnostic, real time and data logging features. The Flowmeter is available in both compact and remote mount versions.
- Highly accurate and stable device
- No moving parts in the flow profile
- Configuration data is backed up and can be recovered
- Robust design
- Datalogging function
- Diagnostic facility
|  |
| Transmitter Specification |
| Minimum Media Electrical Conductivity | =5 µS/cm / =20 µS/cm for de-mineralised water |
| Flow Range | 0.1 - 10 m/s |
| Accuracy | 0.5% (0.5 - 10 m/s) of reading value 1% (0.1 - 0.5 m/s) of reading value |
| Power Supply | 95 - 250V AC (+10%, -20%), 50/60 Hz, 12/14/48V AC/DC (+10%, -15%) |
| Power Consumption | 10 VA |
| Communication | RS485, RS232 |
| Control | RS485, RS232, keyboard and magnetic pointer |
| Electronics Protection | Standard IP67/ Nema 5 (IP68/Nema 6) |
| Housing Material | Die Cast Aluminium |
| Flow Direction | Bi-directional measurement |
| Diagnostics | Diagnostic of internal temperature and power supply voltages |
| Real Time | Real time circuit for datalogging |
| Datalogger | Datalogger memory up to 15000 values (programmable sample rate)
Registration of minimum and maximum flow rate including date and time |
| Hazardous Area Approval | Zone 2 pending |
| Cable Terminals | 2 pieces PG11 |
| Outputs | Frequency 0 - 12 kHz with programmable flow rate and function
Pulse 0 - 50 Hz with programmable volume, function and pulse width
Relay contacts 100V/0.5A with programmable function (as option)
Current 4-20mA with programmable flow rate and function Max 500? |
| Control Principle | Pulsed DC from transmitter |
| Sensor Specification |
| Flange | Steel 1.0402 or higher |
| Nominal Size | 10 to 800mm |
| Maximum Pressure | 1.0 - 2.5 MPa (10/16/25 bar) |
| Maximum Temperature | 70°C (158°F) for hard rubber liner
130°C (266°F) for PTFE liner in remote version |
| Ambient Temperature | -20 to 60°C (-4 to 140°F) |
| Sensor Protection | Standard IP67/Nema 5 (IP68/Nema 6) |
| Liner | Hard rubber, PTFE |
| Measuring Tube | Stainless Steel 1.4201, dimensions according to DIN 17457 |
| Outer Casting | Carbon steel as standard |
| External Coating | Lacquered finish (anticorrosive) |
| Conformity requirements | PED according to directive 97/23/EC |
| Hazardous Area Approval | Zone 2 pending |
|