Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

The Model 910 Electromagnetic Flowmeter is an instrument designed for measuring and indicating flow and total volume of conductive liquids. The flowmeter measures both positive and negative flow. As there are no moving parts in the profile, the device can be used to measure extremely dirty liquids containing solids. The flowmeters have been designed to work in all process industries including chemical, water and wastewater. The Model 910 also boasts diagnostic, real time and data logging features. The Flowmeter is available in both compact and remote mount versions.

  • Highly accurate and stable device
  • No moving parts in the flow profile
  • Configuration data is backed up and can be recovered
  • Robust design
  • Datalogging function
  • Diagnostic facility
Transmitter Specification
Minimum Media Electrical Conductivity=5 µS/cm / =20 µS/cm for de-mineralised water
Flow Range0.1 - 10 m/s
Accuracy0.5% (0.5 - 10 m/s) of reading value
1% (0.1 - 0.5 m/s) of reading value
Power Supply95 - 250V AC (+10%, -20%), 50/60 Hz, 12/14/48V AC/DC (+10%, -15%)
Power Consumption10 VA
CommunicationRS485, RS232
ControlRS485, RS232, keyboard and magnetic pointer
Electronics ProtectionStandard IP67/ Nema 5 (IP68/Nema 6)
Housing MaterialDie Cast Aluminium
Flow DirectionBi-directional measurement
DiagnosticsDiagnostic of internal temperature and power supply voltages
Real TimeReal time circuit for datalogging
DataloggerDatalogger memory up to 15000 values (programmable sample rate)
Registration of minimum and maximum flow rate including date and time
Hazardous Area ApprovalZone 2 pending
Cable Terminals2 pieces PG11
OutputsFrequency 0 - 12 kHz with programmable flow rate and function
Pulse 0 - 50 Hz with programmable volume, function and pulse width
Relay contacts 100V/0.5A with programmable function (as option)
Current 4-20mA with programmable flow rate and function Max 500?
Control PrinciplePulsed DC from transmitter
Sensor Specification
FlangeSteel 1.0402 or higher
Nominal Size10 to 800mm
Maximum Pressure1.0 - 2.5 MPa (10/16/25 bar)
Maximum Temperature70°C (158°F) for hard rubber liner
130°C (266°F) for PTFE liner in remote version
Ambient Temperature-20 to 60°C (-4 to 140°F)
Sensor ProtectionStandard IP67/Nema 5 (IP68/Nema 6)
LinerHard rubber, PTFE
Measuring TubeStainless Steel 1.4201, dimensions according to DIN 17457
Outer CastingCarbon steel as standard
External CoatingLacquered finish (anticorrosive)
Conformity requirementsPED according to directive 97/23/EC
Hazardous Area ApprovalZone 2 pending