Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

The L Series flow transmitters are primarily for use on water but are also suitable for other liquids depending upon viscosity and material compatibility. By measuring the differential pressure produced by flow through a laminar flow element, an inherently linear reading is converted using modern electronics to give a voltage output, with an integral liquid crystal display.

Specification
Flow Rate Max10 L/min
Operating Temperature50.00 ºC
Operating Pressure6.84 BarG
Accuracy±1% of full scale
Power Requirements24 VDC
Process Connection1/8"and ¼" NPT female
Repeatability±1% of full scale
Response Time20 msec
Pressure DropLess than 30mbar
Turndown Ratio50:1
Wetted MaterialsSt.Steel, Viton, Silicon Gel, RTV, Nylon & Polyethermide
Dimensions27 x 61 x 117mm
Power Supply7 to 30 VDC, 30mA typ
Outputs0 to 5VDC (4 to 20mA optional)
Electrical Connection2m long 8-core lead
Display4½ digit LCD
Available Models
Flow RangeCode
0.005-0.5 cm3/minFLM0000
0.01-1.0 cm3/minFLM0001
0.02-2.0 cm3/minFLM0002
0.05-5.0 cm3/minFLM0003
0.1-10 cm3/minFLM0004
0.2-20 cm3/minFLM0005
0.3-30 cm3/minFLM0006
0.5-50 cm3/minFLM0007
2-200 cm3/minFLM0008
5-500 cm3/minFLM0009
0.01-1.0 L/minFLM0010
0.02-2.0 L/minFLM0011
0.03-3.0 L/minFLM0012
0.05-5.0 L/minFLM0013
0.1-10.0 L/minFLM0014