Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

A spring loaded variable orifice meter which can be mounted in any orientation. Oil or water flow moves the orifice along a scale printed on the borosilicate glass tube, to indicate flow rate. Independent of viscosity changes up to 200 cS. The meter body is in polyester with standard 1" BSP threads.

  • Oil and water calibrated
  • Works in any orientation
  • Pressures up to 10 bar
  • Flows 1 to 150 L/min
  • Accuracy ±5% FSD
  • Repeatability ±1% FSD
  • Option of switches
  • Plant and equipment protection
Specification
BodyPolyester with Borosilicate Glass
TemperatureOil - +5 to 80°C, Water - +5 to 60°C
Maximum Pressure10 bar
Accuracy±5% FSD
Electrical switch optionAdjustable 20 – 100% full scale
OutputNon-latching reed switch
Switch Rating1.5A at 240V AC, 0.5A at 48V DC
CalibrationOil (SG 0.856) @ 20°C, Water @ 20°C
Connections1” BSP Female
Available Models
Flow RangeWater @ 20C, meter onlyWater @ 20C, c/w AC/DC SwitchOil @ 20C, meter onlyOil @ 20C
1-15 L/minFEFW0152FEFW0152BFEFL0151FEFL0151B
2-30 L/minFEFW0302FEFW0302BFEFL0301FEFL0301B
4-50 L/minFEFW0502FEFW0502BFEFL0501FEFL0501B
5-100 L/minFEFW1002FEFW1002BFEFL1001FEFL1001B
10-150 L/minFEFW1502FEFW1502BFEFL1501FEFL1501B