Products > Flow > Shunt VA Flowmeters > SGUV Shunt Orifice Flowmeter - Air
Shunt orifice Flowmeters are direct reading flow measurement systems for clean liquids and gases in pipes from 1 1/4" to 24" diameter. By introducing a standard sharp edge orifice plate between flanges on the line, a proportion of the main flow is diverted around the external pipework, through a locally mounted specially calibrated VA meter. The flow through this shunt meter is linearly related to the line flow and is read directly on a linear scale.
|  |
| Specification |
| Flow Rate | 500-25000 L/min |
| Operating Temperature | 80.00 º |
| Operating Pressure | 25 BarG |
| Wetted Materials | Stainless Steel |
| Pipe size | 100.00mm |
| Material | Stainless steel plate mounted in polyester coated steel carrier ring |
| Flanges | Standard BS10 Table E |
| DP Produced | 25" WG for air 100" WG for liquid flows (max) |
| Thickness | Standard 25mm |
| Valves | Dual S/steel isolating valves fitted |
| Tube | Borosilicate glass, l00mm scale |
| Piping | Copper with plated Brass connections Model SGUL uses flexible piping to install indicator at up to 25 feet away |
| Housing | Polyester coated die cast aluminium with perspex window |
| O Ring Seals | Nitrile |
| Options | GIR Alarm (to special order) Designed to suit flange fittings (ANSI, DIN)
Different process fluids or flow ranges
Meters for line sizes up to 24"
All Stainless steel orifice plate |
| Available Models |
| Flow Range (m3/hr) | Pipe Size | Code |
| 30-150 | 1 1/4" | SGUVB1A |
| 40-200 | 1 1/2" | SGUVB2A |
| 80-400 | 2" | SGUVB3A |
| 180-900 | 3" | SGUVB5A |