Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

These simple paddle flow switches are used to monitor the presence or absence of air or liquid flow. The switch can be adjusted by the user from Normally Open (NO) to Normally Closed (NC) easily without interrupting process flow.

Specification
Cables2 x 460mm 22 AWG wire
Operating Temperature93.00 ºC
Operating Pressure69 BarG (brass) or 138 BarG (St. Steel)
Pipe Size1/2" NPT
BodyBrass or 303 Stainless steel
Wetted Materials301, 302, 316 Stainless steel, Ceramic magnet
Dimensions135 x 57 x 23mm
SwitchSingle pole reed switch
Electrical Rating1.5A, 24V DC resistive, 0.5A, 120VAC
Frame301 Stainless steel
Available Models
Water @ 20C (L/min)Air @ ATP,20C (m3/hr)
Pipe SizeNO ActNO DeactNC ActNC DeactNO ActNO DeactNC ActNC Deact
½"9.88.79.89.517.515.017.315.6
¾"11.710.211.710.622.119.721.919.7
1"18.217.018.216.732.629.932.129.9
1¼"23.521.223.121.242.137.741.638.2
1½"31.029.131.029.156.853.056.152.0
2"36.034.436.034.185.382.285.381.1