Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

The float contains a tilt switch and is suspended into the tank or sump from above on the cable. Above the float a weight holds the cable vertical; when the liquid causes the float to rise it switches an SPCO microswitch to trigger an alarm or pump.

It is recommended that this float should be used with a relay module to switch AC power circuits.

Specification
FloatPolypropylene copolymer
CableThick PEC double insulated
Cable Length5m, 10m or 25m
RatingIP68 (to 50 metres)
OutputSPCO 240V AC 10A
Temperature70°C max
Ballast Weight200gm loaded resin (Note: this should be positioned typically 0.5m from float)
Available Models
DescriptionCode
5m cableEC5
10m cableEC10
25m cableEC25