Roxspur Measurement and Control: For Good Measure RM&C LtdPlaton, Brearley, CT, Nulectrohms, SensitPhone 0870 22 00 724 or email sales@roxspur.com

These 100mm recorders range from the simple analogue recorder to a self contained data acquisition system.

4101: The 4101 is available as a 1 to 4 continuous pen instrument with a 4Hz sample rate (4101C) or as a multipoint instrument with up to 6 inputs plotted (4101M). Access to pen zero and span, alarm thresholds, chart speed, time and date is from the font of the recorder. The use of pre-configured inputs allows direct connection of a variety of transducers. Text annotation can print the time, chart speed and channel scales onto the chart.

4102: The 4102 has all the features of the 4101, but has a digital display in place of the analogue scales. The three-colour screen offers large four-digit indication of the measured parameters, channel identification and alarm status. Input types, alarm set point and instrument calibration can all be adjusted using the operator keypad on the display.

4103: The 4103 is available as a 1 to 4 continuous pen instrument with 8Hz sample rate (4103C) or as a multipoint instrument with up to 6 inputs plotted (4103M). The instrument has the option of a PC card to configuration storage, transfer of process data to computer database or spreadsheet packages. Extensive mathematics capabilities include totalisers, timers, and counters. The 4103’s annotation allows scale and message printing and time lagged numerical values.

Specification
Supply Voltage90-260 VAC (DC available)
Temperature Limit0 to 50°C
Humidity \ Limits5 to 80% non-condensing
Size138W x 138H x 257D (4101); 144W x 144H x 257D (4102 & 4103)
Input TypesThermocouples B,C,D,E,G,J,K,L,N,R,S,T,U; ohms RTD, VDC, mA; Digital inputs (4103 only)
Input to Paper Accuracy0.5% (4101 & 4102); 0.25% (4103)
Input to Display Accuracy0.3% (4102); 0.1% (4103)
Chart Size100mm
Transport Accuracy0.5mm in 16 metre
Pen Type (Continuous)Disposable fibre tipped pens
Pen Life3 months typical at 60mm/hr (channel pens)
Pen Colours1: Blue, 2: Red, 3: Green, 4: Violet, Annotation: Black
Pen Resolution0.15mm
Update Rate4Hz (4101 & 4102); 8Hz (4103)
Response Rate2 seconds max (4101 & 4102); 1 second max (4103)
Pen Type (Multipoint)Six nib cartridge
Pen Life3 months typical
Pen Colours1: Violet, 2: Red, 3: Black, 4: Green, 5: Blue, 6: Brown
Pen Resolution0.2mm (4101 & 4102); 0.15mm (4103)
Update Rate1Hz (4101 & 4102); 2Hz (4103)
Response RateAll channels in 5 seconds (4101 & 4102); All channels in 1 second (4103)