Roxspur Measurement and Control: For Good Measure RM&C Ltd

The SmartReader ACR/SRP 12 Bit data loggers satisfy a wide range of applications;- Temperature, Relative Humidity, AC current, Pressure, Process Signals and Pulses can all be measured and recorded. Extended memory options are available on selected ACR/SRP series 12 Bit devices up to 1.5MB. They are powered by an internal battery with a typical life of up to 10 years and programmed by Windows based TrendReader software. The data stored in the logger can be downloaded and either saved to disk or analysed immediately on screen. Information is displayed in tabular or graphical format with full reporting facilities or alternatively the data can be incorporated into other spreadsheet packages. Refer to page 161 TrendReader software.

Specification
Memory Size21500 readings optional 128KB or 1.5MB*1
Sampling Methodscontinuous(First-in, First-out) stop when full (Fill-then-stop)
Sampling Ratesuser selectable from 25 per second (with optional battery pack), 8 seconds to 8 hours
ClockAccuracy ±2 seconds per day plus one sampling interval
BatteryOn board, typical life 10 years
Operating Limits-45°C to +70°C, 0 to 95% RH non condensing
Input ConnectorRemovable, 11 way terminal strip
PC RequirementsA PC with a 386 processor or higher, 2MB of hard drive space, 31/2" floppy drive, 2MB RAM, Windows 3.1 running in enhanced mode.
SoftwareTrendReader® for Windows. Refer to Trendreader entry.
External ConnectorRemovable screw-type terminal strip with Common (-) connection.
Relative Humidity and Temperature Logger
A self contained temperature and relative humidity data logger with optional remote sensors.
Accuracy± 3% 10 to 90% RH
ResolutionBetter than 0.04%
RangeRH 0 - 100% non-condensing
InputIntegral temperature and RH sensors
Accuracy± 3% 10 to 90% RH
Thermocouple Input Temperature Loggers
Provides for up to seven J, K, S or T thermocouples plus one integral cold junction sensor.
Accuracy± 0.5% Full scale plus resolution
ResolutionJ = 0.3°C, K = 0.5°C, S = 0.3°C, T = 0.5°C
Process Signal Input Logger
Designed to accept commercially available transducers that are used to monitor a wide variety of measurement parameters. The TrendReader software enables all input signals to be displayed in engineering units.
Accuracy± 0.5% Full scale
Input7 analogue (0-25mA)
Pulse Loggers
Designed for easy counting and recording of switch closures and voltage pulses.
InputTwo remote logic signals
Pulse Width2 milliseconds
Range32; 64; 128 pulses per second
Switch ContactUncommitted switch or relay contacts
Logic InputActive logic signals
TypeLow = 0 to 0.5 VDC; High = 4.5 to 24 VDC
Impedance750 K ohms
Frequency512 Hz maximum