1. Termination Heads
Ceramic terminal blocks are fitted as standard to all heads
Standard Single Head: General purpose die cast aluminium alloy head with hinged lid.
Standard Duplex Head: Specification as standard single head for duplex thermometers.
Weatherproof Single Head: Cast aluminium alloy head for outside applications and where liquid or moisture ingress is a problem. Incorporating threaded lid, seal, ¾" BSP process thread and 20mm ISO cable entry. The weatherproof single head is also available in cast iron.
Weatherproof Duplex Head: Specification as weatherproof single head for duplex thermocouples.
2. Process Connections
Fixed Welded Process Adaptors: Available in Carbon Steel and Stainless Steel with parallel or tapered thread.
Adjustable Process Adaptors: Available in Carbon Steel and Stainless Steel with parallel or tapered thread.
Flanges - Fixed Welded: Available in Carbon Steel and Stainless Steel to customer specification.
Flanges - Adjustable Standard Sizes
3"(76.20mm) Cast Iron
4"(101.60mm) Cast Iron
5" (127.00mm) Cats Iron
3. Metal Protection Sheaths
253 Cr Ni REM
1100°C Temperature limit
¾" NB x SCH 40 (26.67 x 20.93)
½" NB x SCH 40 (21.34 x 15.80)
5/8" OD x ½"ID (15.87 x 12.70)
54 Cr Fe
1150°C Temperature limit
¾" NB x SCH 40 (26.67 x 20.93)
½" NB x SCH 40 (21.34 x 15.80)
½" OD x ¼" ID (12.70 x 6.35)
600Ni Cr Fe
1150°C Temperature limit
1" OD x ¾" ID (25.40 x 19.05)
¾" OD x ½"ID (19.05 x 12.70)
5/8" OD x ½"ID (15.87 x 12.70)
½" OD x 3/8" ID (12.70 x 9.52)
601Ni Cr Fe Al
1250°C Temperature limit
1" OD x ¾" ID (25.40 x 19.05)
35Ni Cr Fe Si
1300°C Temperature limit
1" OD x ¾" ID (25.40 x 19.05)
5/8" OD x ½" ID (15.87 x 12.70)
Inner impervious refractory sheath fitted on all noble metal thermocouples. Temperature limits subject to operational environment and thermocouple element type.
4. Thermocouple Element
| Base metal | SWG |
| Type K | 10 | 16 | 19 | 22 |
| Type J | 10 | 16 |
| Type N | 10 | 16 |
| Type T | - | 16 |
Conductors conform to BS EN 60584-2: 1993 Class 1 & 2 tolerance
| Noble Metal | Diameter |
| Type R | 0.15mm | 0.35mm | 0.45mm | 0.5mm |
| Type S | 0.15mm | 0.35mm | 0.45mm | 0.5mm |
| Type B* | 0.15mm | 0.35mm | 0.45mm | 0.5mm |
Conductors conform to BS EN 60584-2: 1993 Class 1 tolerance
*Conductors conform to BS EN 60584-2: 1993 Class 2 tolerance
Also available: Other thermocouple Types and Insulated Elements
5. Refactory Sockets
Sheathed T/C Only
Available in Mild Steel and Heat Resisting Steel.
- 2 ¾" Diameter (57.15mm)
- 1 3/8" Diameter (34.92mm)
- 1 5/16" Diameter (1" Nominal Bore) (33.33mm)
- 1 ¼" Diameter (31.75mm)
- 1 1/16" Diameter (3/4" Nominal Bore) (26.98mm)
- ¾" Diameter (19.05mm)
- 5/8" Diameter (15.87mm)
- ½" Diameter (12.70mm)
6. Refractory Protection Sheaths
Aluminous Porcelain*
Temperature limit: 1400°C
| Socket Size |
| 20mm OD x 15mm ID | 3 or 4 |
| 17mm OD x 13mm ID | 5 |
| 12mm OD x 8mm ID | 6 |
| 10mm OD x 7mm ID | 7 |
| 8mm OD x 5mm ID | 8 |
Recrystalised Alumina
Temperature limit: 1800°C
| Socket Size |
| 20mm OD x 15mm ID | 3 or 4 |
| 17mm OD x 13mm ID | 5 |
| 12mm OD x 8mm ID | 6 |
| 10mm OD x 7mm ID | 7 |
| 8mm OD x 5mm ID | 8 |
Silicon Carbide
Temperature limit: 1450°C
| Socket Size |
| 50mm OD x 25mm ID | 1 |
| 31mm OD x 15mm ID | 2 |
Temperature limit subjected to operational environment and thermocouple element type.
* Not recommended above 1200°C for noble metal thermocouples. |