• Flow.Temperature.Pressure.Level.Pumps

  • Measurement.Repair.Environmental.Calibration

  • UKAS.NADCAP.Traceable.Certification

 

Platon Averaging Pitot Tube: Flo-Bar

Can we help?
The Flo-Bar is an Averaging Pitot Tube flow sensor for use on pipes/ducts or chimneys. Differential pressure created across the Flo-Bar has the standard square root relationship to flow rate, making a simple, removable sensor for installation or retrofit on flowlines of any size.

The unique design of the Flo-Bar profile provides a high accuracy, wide rangeability sensor: the standard integral manifold allows simple process isolation and easy installation of a DP measurement cell.
  • Flow sensor for liquids, gases or steam
  • ± 1% Accuracy with standard square root flow output
  • Full electron beam welded construction
  • Unique profile sensor with flow averaging
  • Integral 3 valve manifold
  • Simple direct mounting of DP transmitter if required
  • Plain head and remote manifolds available
  • An in-line version for small pipes is also available.

Full Product Specification

 
Probe Diameter 13mm for 50-449mm diameter pipes
25mm standard, 100-3,000mm pipes
60mm for pipes over 3,000mm ID
Material Stainless Steel, electron beam welded construction.
Averaging Sensor Typically 6 upstream ports for flow averaging
Installation 7 diameters downstream, 3 diameters upstream (minimum) of a bend or similar obstruction
Process Connections ¼" NPT Female on 54mm centres from integral 3-way manifold
Accuracy ±1% actual reading
Flow Repeatability ±0.1%
APE Connection Locking gland or flanged
Process Connections ¼" or ½" NPT Plain Head
Temperature Limitation Locking gland: 90°C (1 barg), flange to flange rating
3-way manifold: 232°C (300°C) Graphfoil seal
 Pressure Limitation Locking gland: 5 bar, flange to flange rating

Recommended Products